Saltar al contenido principal

Xishan Medical

Spine Surgery Solutions

Solution Overview

  • CORE VISUALIZATION 4K UHD Spine Endoscopy & Foraminoscopy System (PELD / UBE)
  • ENERGY DISSECTION UT-C-S1 Selective Ultrasonic Bone Scalpel (24.5kHz)
  • TISSUE CLOSURE DK-O-MVS High-Speed Power System & Bipolar RF Coagulation
  • TARGET SPECIALTIES Spine Surgery, Orthopedics, Neurosurgery & Interventional Spine
Spine Surgery & Minimally Invasive Spine Care

Precision Bone Cutting & Advanced Endoscopic Spine Preservation

XISHAN’s Total Solution for Spine Surgery seamlessly integrates ultrasonic selective bone scalpel technology, ultra-high-speed power burring, 4K endoscopic visualization, and radiofrequency bipolar hemostasis into a unified surgical platform. Designed for spine surgeons and neurosurgeons, this ecosystem elevates surgical safety in complex spinal decompressions and minimally invasive interventions.

By leveraging selective ultrasonic bone resection that cuts mineralized tissue while sparing delicate nerves, dura mater, and blood vessels, surgical teams achieve unprecedented procedural control across PELD, UBE, laminectomy, and spinal fusion procedures.

orthopedics_banner

01. Surgical Applications & Procedures

Engineered for maximal neurological protection and spinal stability, XISHAN’s spine solution provides tailored performance across key open and endoscopic procedures:

  • Percutaneous Endoscopic Lumbar Diskectomy (PELD / TESSYS)
  • Unilateral Biportal Endoscopy Decompression & Fusion (UBE)
  • Cervical & Lumbar Laminectomy and Canal Decompression
  • Complex Spinal Tumor Resection & Deformity Osteotomy

02. Integrated Technical Specifications

Detailed performance parameters of core hardware components engineered for soft-tissue sparing bone cutting and high-speed burring:

03. Value for Hospitals & Distributors

Adopting a unified XISHAN solution streamlines procurement, lowers long-term operational costs, and minimizes surgical risk:

  • Complete Single-Vendor Ecosystem (Ultrasonic, Power, Endoscopy & RF)
  • Enhanced Patient Safety & Sparing of Delicate Dural/Nerve Structures
  • Shortened Surgical Learning Curve & UBE/PELD Hands-On Masterclasses
  • High-Margin Recurring Revenue with Autoclavable Tips & Burrs

04. Solution Configurator & Quote List

Systematically evaluating surgical volume and procedure focus ensures optimal console, ultrasonic scalpel, and endoscopic instrument configuration:

  • Selective Bone Cutting Technology Protecting Nerves & Dura Mater
  • 80,000 RPM High-Speed Micro-Burring with <0.01mm Precision Runout
  • Complete Compatibility with PELD, UBE, and Open Spine Surgeries
  • Full Array of Autoclavable Ultrasonic Tips & Diamond Burrs
  • Customized B2B Ultrasonic, Power, & Endoscopy Package Quotations

Spine Surgery Solutions

Full-spectrum minimally invasive spine surgery solution integrating heavy-duty power mainframes (DK-O-MVS), selective ultrasonic bone scalpels (UT-C-S1), arthro plasma ablation (PLA-CHA-OS1), bipolar RF units (RF-CHA-S1), and PELD/UBE spinal endoscopes (EDS-ART-SPINE).

Descripción

The XISHAN Total Solution for Spine Surgery is a specialized, multi-modality surgical platform engineered for full-endoscopic spine surgery (PELD / PETD / PEID), Unilateral Biportal Endoscopy (UBE), and complex open spinal decompression and fusion. Integrating variable-angle high-speed power burs (DK-O-MVS), tissue-selective ultrasonic bone scalpel technology (UT-C-S1), low-temperature plasma / RF energy platforms (PLA-CHA-OS1 & RF-CHA-S1), and large-channel operative spinal endoscopes (EDS-ART-SPINE), it provides spine surgeons with a unified ecosystem for bone resection, disc modulation, and neural protection.

This multi-energy synergy addresses the core technical challenges of minimally invasive spine surgery (MISS): navigating narrow anatomical corridors, safely removing bone adjacent to the dural sac and exiting nerve roots, instantly arresting epidural venous bleeding, and maintaining clear endoscopic visualization under continuous saline irrigation.

Core Spine Operative Modalities

Articulating Spine Bur Drilling (DK-O-MVS)

Supports stepless 0–36° bendable spinal burs and 4.5mm slim telescoping sleeves for precision transforaminal foraminoplasty and ventral osteophyte grinding around curved anatomical angles.

Tissue-Selective Bone Resection (UT-C-S1)

24.5 kHz ultrasonic bone scalpel cleanly cuts the vertebral lamina and resects OPLL calcifications with an ultra-narrow 0.8mm kerf while inherently safeguarding the dural sac and nerve roots.

Low-Temp Plasma & RF Modulation

PLA-CHA-OS1 and RF-CHA-S1 platforms deliver localized plasma ablation (40°C–70°C) and megahertz bipolar coagulation for nucleus pulposus vaporization, annuloplasty, and epidural venous hemostasis.

Large-Channel Spine Endoscopy

EDS-ART-SPINE provides up to φ4.3mm large instrument channels and dual dedicated inflow/outflow irrigation ports with 30° panoramic optics for crystal-clear visualization during PELD and UBE.

Integrated Suite Configuration Matrix

System ComponentModel / SKUClinical Role & Key Technical Specifications
Heavy-Duty Spine Power MainframeDK-O-MVS200W brushless motor, 0–36° bendable spine burs, JJT sagittal saws, cannulated bone drills
Ultrasonic Bone ScalpelUT-C-S124.5 kHz selective bone cutting, 0.8mm narrow kerf, 1.8mm cervical/lumbar milling tips, dura protection
Arthro & Spine Plasma UnitPLA-CHA-OS1100 kHz low-temperature coblation (40°C–70°C), 350W ablation / 49W coagulation, extended hip/spine probes
High-Frequency RF UnitRF-CHA-S14.0MHz monopolar / 1.7MHz bipolar generator, 5 output modes, steerable & straight spinal RF electrodes
Transforaminal Spine EndoscopeEDS-ART-SPINEφ6.9mm OD, φ4.3mm large working bore, 181mm length, 30° wide angle, dual irrigation flow valves

Clinical Indications & Surgical Scope

  • Percutaneous Endoscopic Transforaminal Discectomy (PETD): L1–L5 lumbar disc herniation, foraminal stenosis, and bone foraminoplasty under direct vision.
  • Percutaneous Endoscopic Interlaminar Discectomy (PEID): L5/S1 disc extrusion, axillary herniations, and interlaminar ligamentum flavum resection.
  • Unilateral Biportal Endoscopy (UBE): Biportal endoscopic spinal decompression, spinal canal stenosis clearance, and lumbar interbody fusion (ULIF).
  • Cervical & Thoracic Decompression: Anterior cervical discectomy and fusion (ACDF), posterior cervical open-door laminoplasty, and thoracic ossification of ligamentum flavum (OLF) resection.
  • Complex Spine Reconstruction & Fusion: Transforaminal Lumbar Interbody Fusion (TLIF), Posterior Lumbar Interbody Fusion (PLIF), and osteophyte decompression.

Benefits for Surgical Centers & Procurement Teams

  • Complete PELD / UBE / Open Workflow: Covers the entire operative progression from skin entry, foraminoplasty, and ultrasonic laminotomy to endoscopic fragmentectomy and bipolar hemostasis.
  • Maximum Neurological Safety: Selective bone cutting combined with sub-millimeter thermal margin plasma ablation strictly prevents thermal and mechanical trauma to nerve roots.
  • Flexible Modular Procurement: Consoles and handpieces can be configured as a complete all-in-one workstation or integrated modularly into existing OR infrastructure.
  • Standardized Global Quality: Fully compliant with ISO 13485 quality systems and CE Mark standards with comprehensive warranty and clinical training support.

Información adicional

Clinical Application

Product Form

Global Strength & Innovation

Inquiry & Support

Get in Touch With Us

For product inquiries, distribution partnerships, technical support, or academic collaboration, please connect with us directly.

Global Reach

Global Innovation & Support Network

Latin & North America

Regional Lead:  Ashlynn Luo

1 of 23

CIS

Regional Lead:  Mila Xiao

2 of 23

Asia-Pacific 1

Regional Lead:  Freya Chen

3 of 23

Europe

Regional Lead: George Xiong

4 of 23

Asia-Pacific 2

Regional Lead:  Jack Ju

5 of 23

Middle East & Africa

Regional Lead:  Michael Xu

6 of 23

Chongqing, China
Global Headquarters & R&D Base
1,329 Patents | National Standard Drafter
Certifications: NMPA, CE, ISO 13485

7 of 23

8 Patents & Trademarks Applied
Certifications: CE, ISO 13485

8 of 23

4 Patents & Trademarks Applied
Certifications: CE, ISO 13485

9 of 23

4 Patents & Trademarks Applied
Certifications: CE, ISO 13485

10 of 23

1 Patents & Trademarks Applied
Certifications: CE Mark, ISO 13485

11 of 23

8 Patents & Trademarks Applied
Certifications: CE Mark, ISO 13485, ISO 9001

12 of 23

4 Patents & Trademarks Applied
Certifications: CE, ISO 13485

13 of 23

3 Patents & Trademarks Applied
Certifications: CE, ISO 13485

14 of 23

5 Patents & Trademarks Applied
Certifications: CE, ISO 13485

15 of 23

7 Patents & Trademarks Applied
Certifications: CE, ISO 13485

16 of 23

3 Patents & Trademarks Applied
Certifications: CE, ISO 13485

17 of 23

2 Patents & Trademarks Applied
Certifications: CE, ISO 13485

18 of 23

3 Patents & Trademarks Applied
Certifications: CE, ISO 13485

19 of 23

3 Patents & Trademarks Applied
Certifications: CE, ISO 13485

20 of 23

4 Patents & Trademarks Applied
Certifications: CE, ISO 13485

21 of 23

5 Patents & Trademarks Applied
Certifications: CE, ISO 13485

22 of 23

8 Patents & Trademarks Applied
Certifications: KFDA, CE, ISO 13485

23 of 23